DATA CENTER INFRASTRUCTURE



Two UPS Schneider Symmetra PX is UPS System. Features are as follows.

Features:

  • User-replaceable batteries

                  Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR)

  • User-replaceable power modules

                 Enables simple upgrades and replacements of the Power Modules.

  • ·Fully-rated power kVA equals kW

               Reduces cost by eliminating the need for an oversized UPS for Power Factor Corrected (PFC) loads.

  • ·Network manageable

               Provides remote power management of the UPS over the network.

  • ·Modular design

              Provides fast serviceability and reduced maintenance requirements via self-diagnosing, field-replaceable modules.

  •    Power Modules connected in parallel

          Enhances availability by allowing immediate, seamless recovery from isolated module failures.

  • · Scalable power capacity

          Reduces UPS over-sizing costs today by allowing quick power upgrades, within the same footprint, later.

  • Configurable for N+1 internal redundancy

           Provides high availability through redundancy by allowing configuration with one more Power Module than is necessary to support the connected load.

  • Generator compatible

             Ensures clean, uninterrupted power to protected equipment when generator power is used.

  • Battery modules connected in parallel

            Delivers higher availability through redundant batteries.

 

 

Two UniFlair TDAR

 

 

 

  • Multi-functional Microprocessor Controlle                                                                                                                                                                                                   Allows the units to restart after a power failure without intervention; Allows for room level redundancy with up to ten units operating in a group; User friendly                   navigation with icon based displays to indicate mode of operation as well as room conditions; Allows for communication with multiple Building Management System protocols.
  • Active response contro                                                                                                                                                                                                                        Monitors and actively adjusts cooling capacity to ensure proper server inlet temperatures. Through the microprocessor controller, visibility into the operation and           status of the unit is provided.
  • Redundant Components

             Single points of failure in the system have redundant compononents to maintain availability and reliability.

  • Electronic expansion valve

             Refrigerant flow optimization at any load and temperature conditions. Continuous indirect refrigerant charge monitoring

  • Direct drive motors

            Stress on bearings is nearly eliminated, increasing useful life. Allows integral fan/motor assembly to be factory balanced, which lowers vibration and expedites startup.

 

Two Generators (200 KVA & 500 KVA) with 2 AMF Panel

 

 

 

Features 

  • 180 Ltr Internal Fuel (Diesel) Tank for 200 KVA and 500 KVA respectively 
  • Sound Proof Enclosure
  • Weather Proof Enclosure
  • UC274H/HCI544D Alternator for 200 KVA & 500 KVA respectively 

 

 

Special Features of AMF Panel/Diesel Generator

 

 

  • Automatically Start the Generator when main Fails
  • Automatically Stop the Generator when the main is restored.
  • Automatically changes the lines from Main to Gen. & Vice versa
  • Changing over to Main line with the delay. (Programmable).
  • Genset stop with the further delay. (Programmable)
  • Manual Start & Stop Switch.

 

Cloud Himalaya is located in one of the most convenient and central location of Kathmandu equally accessible to all corporate enterprises.

•    Own data center site not in rent or lease .  No worries about lease expiration and movement.
•    Seismic safe building standing still and safe despite facing 7.8 Mw of earthquake on April 25, 2015
•    24X7-perimeter surveillance surrounded by high wall and onsite security guard 
•    24X7 Video surveillances on 360 view inside data center with 3 months backup and archive
•    200 KVA & 500 KVA multiple backup diesel generator working in sync mode 
•    Redundant UPS with 30 min battery backup 
•    RACK with 5 KW power supply along with customizable capacity as per customer needs 
•    Fuel storage to sustain 4 Months in complete power outage
•    Redundant 40 Gbps fiber bandwidth for intranet and internet connecting the fiber ring in KTM 
•    Internet on demand within from Cloud Himalaya ISP or on customer choice 
•    FM 200 fire suppression agent ready to get deployed upon exceeding specified smoke particles 
•    Ergonomic Hot and cold Isle design with redundant PAC keeping the temp always within 
•    Redundant Cabling with color coding, tag, patch panel managed in database accessible via apps 
•    Data Center critical facility monitoring probe installed and monitored round the clock